Description
QH400E MINI PRO Multi-functional OTDR integrates OTDR, OPM, VFL, Laser Source, Loss Test and RJ45 Sequence in one unit. It is a powerful and economic tester for installers of fiber cable and network cable.
Features:
Integrated design, smart and rugged
FC/SC/ST connectors interchangeable
Automatic and manual test function
Visual Fault Locator (VFL) function
OTDR Viewer software for data analysis
Applications:
CATV network testing
Access network testing
LAN network testing
Laband Factory testing
FTTA troubleshooting
Multi-functions:
1. OTDR
2. Optical Power Meter (OPM)
3. Visual Fault Locator (VFL):Visual Fault Locator uses red laser of 650nm to locate broken fiber point and test fiber continuity.
4. Optical Laser Source (Laser)
5. Loss Test:OPM and OLS can be opened at the same time to test insertion loss.
6. RJ45 Sequence (RJ45 Seq.):It can check wire map of RJ45 cable.
7. Flashlight
8. Report Print:PC software helps print out OTDR test reports.
Specification:
1. OTDR
|
Model |
QH400E |
|
Wavelength |
1310/1550nm |
|
Dynamic Range① |
24/22dB |
|
Fiber Type |
SMF |
|
Event Dead Zone② |
3m |
|
Attenuation Dead Zone |
8m |
|
Measurement Range |
500m/1km/2km/4km/8km/16km/32km/60km |
|
Pulse Width |
5ns/10ns/20ns/30ns/50ns/80ns/160ns/320ns/500ns/800ns/1000ns/2000ns/3000ns/5000ns/8000ns/10000ns |
|
Ranging Accuracy |
±(1m+Sampling Interval +0.005%×Test Distance) |
|
Linearity |
±0.2dB/dB |
|
Sampling Resolution |
0.05~8m |
|
Samping Points |
16~128K |
|
Loss Resolution |
0.01dB |
|
Loss Threshold |
0.2dB |
|
Range Resolution |
0.0001m |
|
Refractive Index |
1.40000~1.49900 |
|
Reflection Accuracy |
±3dB |
|
File Format |
SOR standard file format |
|
Loss Analysis |
4-point method / 5-point method |
|
Laser Safety Level |
Class II |
|
Adapter |
FC (Interchangeable SC adapter) |
|
Language |
English, Russian, Spanish, Vietnamese, Chinese |
Note:
①Testing temperature is 25°C±2°C, maximum pulse width, average time is more than 3 minutes.
②Test conditions of Event Dead Zone are minimum range, minimum pulse width, reflection loss of optical fiber end surface (>45dB), typical value.
2. Optical Power Meter
|
Wavelength Range |
800~1700nm |
|
Calibrated Wavelength |
850/1270/1300/1310/1490/1550/1577/1625nm |
|
Test Range |
-50~+26dBm |
|
Resolution |
0.01dB |
|
Uncertainty |
±5% |
|
Frequency Identification |
CW/270Hz/1kHz/2kHz |
|
Connector |
Universal 2.5mm (FC/SC/ST) |
3. Optical Light Source
|
Emitter Type |
FP-LD |
|
Working Wavelength |
1310/1550nm±20nm |
|
Output Power |
≥-5dBm |
|
Modulation Frequency |
CW/270Hz/1kHz/2kHz |
|
Accuracy |
CW, ±0.5dB/15min (Test after 15 minutes of preheating) |
|
Connector |
FC (Interchangeable SC adapter) |
Note:
3.1. The wavelength of Optical Light Source is the same as OTDR wavelength.
3.2. Optical Light Source shares the same fiber port as OTDR port.
4. Visual Fault Locator
|
Wavelength |
650nm±20nm |
|
Power |
≥10mW |
|
Mode |
CW/1Hz/2Hz |
|
Connector |
Universal 2.5mm (FC/SC/ST) |
5. RJ45 Sequene
|
Test Range |
300m |
Other Specification:
|
Display |
3.5 inch color LCD |
|
Power Supply |
AC/DC adapter: Input: 100~240VAC, 50/60Hz, 0.4A; Output: 5V, 2.0A; Lithium battery: 3.7V, 4000mAh |
|
Battery Standby Life |
≥20h |
|
Battery Working Hours |
≥12h |
|
Communication |
Micro USB |
|
Data Storage |
Internal: 600 curves; External: TF card (not included) |
|
Net Weight |
0.4kg |
|
Size |
173*82*37mm |
|
Operating Temperature |
-10 ~ +50°C |
|
Storage Temperature |
-40 ~ +70°C |
|
Relative Humidity |
0~95% Non-condensing |
|
Warranty |
2 years |
Standard Accessories:
|
Item |
Name |
Quantity |
|
1 |
OTDR with FC Adapter |
1pc |
|
2 |
AC/DC Power Adapter |
1pc |
|
3 |
Data Line |
1pc |
|
4 |
SC Adapter for OTDR Port |
1pc |
|
5 |
User Manual |
1pc |
|
6 |
Calibration Certificate |
1pc |
|
7 |
Soft Bag |
1pc |
Optional Accessories:
|
Item |
Name |
Quantity |
|
1 |
LC Adapter |
1pc |
|
2 |
ST Adapter |
1pc |
Ordering Information:
|
Model |
QH400E |
|
Connector |
None: FC/UPC and SC/UPC (default) |
|
A: FC/APC and SC/APC |
English